Out of the box thinking

Single bay 2 door cabinet, 1200W x 550D x 1810H

Single bay 2 door cabinet, 1200W x 550D x 1810H

The Single Bay 2 Doors Cabinet 1200W x 550D x 1810H is a mid-capacity outdoor enclosure designed for transport and infrastructure applications. Its dual-door configuration supports efficient access and equipment segregation, making it suitable for power distribution, control systems, and communications equipment.

Features a three-point locking system with swing-handle padlock, internal door with meter mount, an optional generator extension, two 600 mm DIN mounting rails, internal gear tray, five-sided insulation, thermostat-controlled twin-fan cooling system, and LED lighting with automatic door switch. Supplied mounted on an optional 300 mm front-access aluminium plinth.

Constructed with a cross-folded roof from 2.5 mm marine-grade material and finished in durable UV RPE Almond Ripple powder coat, compliant with AS/NZS 2312.1:2014 for atmospheric corrosion protection. Optional finishes include Karaka Green (RAL 6015), Almond Ripple (RAL 1015), and T33 Smoke Blue (AS2700). An NZTA-approved anti-graffiti coating in accordance with NZTA S10 is also available.

SKU: OE1B2D12055181 (ESDG02) Categories: , Tags: ,
Share:

Additional information

Product description

The Single Bay 2 Doors Cabinet 1200W x 550D x 1810H is designed for infrastructure environments requiring increased internal capacity while maintaining a consistent cabinet format.

As part of the Single Bay 2 Doors Cabinet series, this model provides a balanced solution between footprint and usable internal space. The dual-door design improves accessibility and supports structured equipment layout for maintenance and operational efficiency.

This cabinet is suitable for outdoor installations where additional equipment volume is required without moving to a larger multi-bay enclosure.

Manufactured from 2.5 mm marine-grade material, the cabinet provides long-term durability in harsh roadside environments. A cross-folded roof enhances weather protection and structural strength. The enclosure is finished in a high-performance UV RPE Almond Ripple powder coat, aligned with AS/NZS 2312.1:2014 for atmospheric corrosion protection. Optional finishes include Karaka Green (RAL 6015), Almond Ripple (RAL 1015), and T33 Smoke Blue (AS2700). An NZTA-approved anti-graffiti coating compliant with NZTA S10 is also available.

The cabinet features two external doors and an internal door fitted with a meter mount, enabling clear separation of metering, power, and control equipment. Optional feature is either to have a hole for own generator connection or including a generator extension connection, allowing temporary or emergency power supply to be safely integrated during outages or maintenance operations.

Internally, the enclosure includes two 600 mm DIN mounting rails and an internal gear tray, supporting organised installation of electrical and control components. The cabinet is insulated on five sides, improving thermal stability and protecting sensitive equipment.

Thermal management is achieved through a thermostat-controlled twin-fan cooling system, ensuring reliable heat dissipation under varying load conditions. LED internal lighting, activated by an automatic door switch, provides safe and efficient visibility during servicing.

Security is provided by a robust three-point locking system with swing-handle padlock, ensuring controlled access to critical infrastructure. The cabinet can be supplied mounted on an optional 300 mm front-access aluminium plinth, facilitating ergonomic access and straightforward roadside installation.

This cabinet delivers a standards-compliant, generator-ready solution for NZTA roadside ITS and electrical installations, combining durability, security, thermal performance, and operational flexibility for long-term field deployment.

Available sizes in this series:

Related products

Please answer the following eight questions to help us better understand your requirements

Custom Indoor Cabinet

Type
2
Mounting
3
Width
4
Depth
5
Rack Units
6
Front Doors
7
Rear Doors
8
Review
Step 1 of 8 Cabinet Type
Step 2 of 8 Mounting Type
Step 5 of 8 Width
Step 4 of 8 Equipment Depth
Step 3 of 8 Rack Units
Step 6 of 8 Front Doors
Step 7 of 8 Rear Doors
Your selected options
Type of Cabinet:
Equipment Mounting:
Required Width:
Required Depth:
Height in Rack Units:
Front Door Option:
Rear Door Option:
Lastly...

If there’s anything specific you'd like us to know, such as unique requirements, concerns, or project details, feel free to add it in the message box below

Custom Outdoor Cabinet

Type
2
Mounting
3
Rack Units
4
Depth
5
Plinth
6
Shelving
7
Cooling
8
Locking
9
Review
Step 1 of 8 Cabinet Type
Step 2 of 8 Mounting Type
Step 3 of 8 Rack Units
Step 4 of 8 Equipment Depth
Step 5 of 8 Plinth
Step 6 of 8 Shelving
What type of equipment support / shelving is required? *
Step 7 of 8 Cooling
Step 8 of 8 Locking
Your selected options
Type of Cabinet:
Equipment Mounting:
Mounting Capacity in Rack Units:
Maximum Equipment Depth:
Standard 100mm Plinth required?:
Required Shelving:
Required Cooling Type:
Required Locking Type:
Lastly...

If there’s anything specific you'd like us to know, such as unique requirements, concerns, or project details, feel free to add it in the message box below

This is where useful sizing information goes
We have received your request!
One of our team will be in touch as soon as possible to discuss your requirements